FINISHED PRODUCT

Dimensional inspection

ISO 3126:2005 · measurement of dimensions of thermoplastics pipes and fittings

STANDARDISED

Pipe and socket compatibility: the basis of weld quality.

Purpose and principle

Check the geometric dimensions of PP-R pipes and fitting sockets, then compare each reading against the tolerances applicable to the product being inspected.

Conditions / parameters

ParameterPP-R pipePP-R fitting
CharacteristicsOutside diameter (Ø ext.); wall thickness (e).Functional dimensions D1, D2, D3 and L.
Measurement points6 readings per characteristic (illustrated case).Number and location according to the inspection plan.
InstrumentsSuitable, verified caliper / micrometer.Caliper, depth gauge and suitable measuring equipment.

Test setup

Dimensional inspection du tube et du raccord PP-R.
PIPE · cross-section with 6 positions. FITTING · socket dimensions. D1, D2: socket diameters · D3: bore dimension · L: socket depth.

Test procedure

Pipes

  1. Identify the size and tolerances.
  2. Check cleanliness and the measuring equipment.
  3. Measure the outside diameter and wall thickness at the 6 points.
  4. Compare each reading against its limits.

Fittings

  1. Identify the item and its dimensional drawing.
  2. Check the sockets and instruments.
  3. Measure D1, D2, D3 and L at the specified points.
  4. Assess each inspected dimension.

Expression / calculation

Mean x̄ = (x1 + x2 + … + xn) / n
Range = xmax − xmin
Unit: mm

Decision rule

Conformity is assessed for each individual measurement. A mean within tolerance does not compensate for an out-of-tolerance reading.