FINISHED PRODUCT

Internal pressure resistance

ISO 1167-1:2006 / ISO 1167-2:2006

STANDARDISED

Hydrostatic resistance at elevated temperature, under a stress of 4.40 MPa (20 bar at 95 °C).

Purpose and principle

Assess the resistance of a PP-R pipe to internal hydrostatic pressure while it is subjected to constant pressure at a controlled temperature for a specified duration. Testing of welded joints is carried out separately on assemblies.

For this test campaign, the documented specimen is a closed pipe: the result describes its hydrostatic resistance. The strength and leak-tightness of assemblies are assessed in separate tests.

Conditions / parameters

ConfigurationClosed pipe · water-in-water
Documented conditions95 °C / 20 bar
Preconditioning3 h
MonitoringPressure, temperature and duration

Test setup

Internal hydrostatic pressure test · pipe in a temperature-controlled bath and pressure supply.

Test procedure

  1. Prepare and measure the pipe; install the end caps.
  2. Fill with water without residual air and condition in the thermostatic bath.
  3. Apply the specified test pressure.
  4. Monitor temperature, pressure and duration until the specified end time or failure.

Expression / calculation

p [bar] = (20 × σ [MPa] × emin) / (dem − emin)