BRASS INSERTS

Mechanical testing of inserts

Qualification of the insert installed in its PP-R fitting

DECLARED

The stated performance applies to the complete fitting, with the brass insert overmoulded in the PP-R body.

Declared torque resistance> 65 N·m
Declared pull-out resistance> 10,000 N

Manufacturing and assembly inspection

Inspection areaTechnical checks
DimensionsOutside/inside diameters, length, shoulder, groove depth and lug height.
Internal threadsThread profile and condition.
OvermouldingInsert position, integrity of the PP-R around the lugs and grooves, absence of cracks and any relative movement.

Torque and pull-out resistance

Mechanical tests on the complete PP-R fitting · torque and axial pull-out.

Torque (torque wrench)

The fitting body is secured without deformation. A threaded adaptor engaged in the insert receives a progressively increasing torque. Declared value: > 65 N·m, without insert rotation, cracking or damage to the PP-R.

Axial tension (pull-out)

The PP-R body is secured and a force is applied along the insert axis. Declared value: > 10,000 N (10 kN), without extraction or damage to the anchorage.

Relationship between geometry and loading

  • The lugs lock the insert in place and resist rotation under torque.
  • The anchoring grooves, which fill with PP-R during overmoulding, resist extraction under tensile loading.
  • Resistance depends on the geometry of these features, the thickness of the PP-R body and the quality of the overmoulding.

Technical interpretation of the results

Result and scopeAssessment of the insert’s resistance to rotation within the PP-R body under the applied torque; tensile resistance is assessed in a separate test.
Additional checkThe strength and leak-tightness of the female–male connection are checked separately by pressurising the assembly.
Technical relevanceVerification of the insert anchorage during tightening. The measured values do not automatically constitute recommended installation torques.